Skip to content

Teradata Teradata Troubleshooting

When Test connection or an operation fails on a Teradata datastore, the error message points to the layer that failed: the credentials, the access rights, or the connection to the database.

Problems every connector shares

A server that cannot be reached, a red status dot, a credential changed at the source, Secrets Management errors, an empty schema list, missing tables, and a blocked deletion are covered on Source Datastore Troubleshooting. This page covers the errors specific to Teradata.

Common Errors

Error Likely Cause Fix
Authentication failed Incorrect username or password Verify the credentials and ensure the user exists in the Teradata system
User does not have SELECT access The user lacks SELECT on the target database or table Run GRANT SELECT ON <database_name> TO <user>
User does not have SHOW access The user lacks SHOW on the target database Run GRANT SHOW ON <database_name> TO <user>
Connection refused The Teradata server is not reachable or the port is incorrect Verify the host and port, and ensure the Teradata server allows connections from the Qualytics IP
Database does not exist The database name provided in the connection form is incorrect Verify the database name with SELECT DatabaseName FROM DBC.DatabasesV

Detailed Notes

Authentication Errors

The error Authentication failed indicates that the credentials are incorrect.

Common causes:

  • Incorrect password: the password does not match the one set for the user.
  • User does not exist: the username was misspelled or does not exist in the Teradata system.
  • LDAP authentication: if LDAP is enabled, the credentials must match the LDAP directory, not the Teradata internal user store.

Note

Teradata authentication can be configured to use internal, LDAP, or Kerberos mechanisms. Ensure the authentication method in the connection form matches the server configuration.

Permission Errors

The error User does not have SELECT access means the user authenticated successfully but lacks the necessary grants on the target database.

Common causes:

  • Missing SELECT on database: the user does not have SELECT on the target database or specific tables.
  • Missing SHOW on database: the user cannot view object definitions needed for metadata discovery.
  • Access to system databases: the user is trying to access a filtered system database (e.g., DBC, SYSLIB).

Connection Errors

The error Connection refused means the Teradata server is not reachable from Qualytics. Check the host and the port (default 1025), and that the server is running and not in a maintenance state. For the network path, see Reaching the Data Source.