# Teradata Teradata Troubleshooting

Source: https://userguide.qualytics.io/source-datastore/datastore/jdbc/teradata/troubleshooting/

When **Test connection** or an operation fails on a Teradata datastore, the error message points to the layer that failed: the credentials, the access rights, or the connection to the database.

> **Info: Problems every connector shares**
>
> A server that cannot be reached, a red status dot, a credential changed at the source, Secrets Management errors, an empty schema list, missing tables, and a blocked deletion are covered on [Source Datastore Troubleshooting](https://userguide.qualytics.io/source-datastore/datastore/troubleshooting/). This page covers the errors specific to Teradata.

## Common Errors

| Error | Likely Cause | Fix |
| --- | --- | --- |
| `Authentication failed` | Incorrect username or password | Verify the credentials and ensure the user exists in the Teradata system |
| `User does not have SELECT access` | The user lacks `SELECT` on the target database or table | Run `GRANT SELECT ON <database_name> TO <user>` |
| `User does not have SHOW access` | The user lacks `SHOW` on the target database | Run `GRANT SHOW ON <database_name> TO <user>` |
| `Connection refused` | The Teradata server is not reachable or the port is incorrect | Verify the host and port, and ensure the Teradata server allows connections from the Qualytics IP |
| `Database does not exist` | The database name provided in the connection form is incorrect | Verify the database name with `SELECT DatabaseName FROM DBC.DatabasesV` |

## Detailed Notes

### Authentication Errors

The error `Authentication failed` indicates that the credentials are incorrect.

Common causes:

- **Incorrect password**: the password does not match the one set for the user.
- **User does not exist**: the username was misspelled or does not exist in the Teradata system.
- **LDAP authentication**: if LDAP is enabled, the credentials must match the LDAP directory, not the Teradata internal user store.

> **Note**
>
> Teradata authentication can be configured to use internal, LDAP, or Kerberos mechanisms. Ensure the authentication method in the connection form matches the server configuration.

### Permission Errors

The error `User does not have SELECT access` means the user authenticated successfully but lacks the necessary grants on the target database.

Common causes:

- **Missing `SELECT` on database**: the user does not have `SELECT` on the target database or specific tables.
- **Missing `SHOW` on database**: the user cannot view object definitions needed for metadata discovery.
- **Access to system databases**: the user is trying to access a filtered system database (e.g., `DBC`, `SYSLIB`).

### Connection Errors

The error `Connection refused` means the Teradata server is not reachable from Qualytics. Check the host and the port (default 1025), and that the server is running and not in a maintenance state. For the network path, see [Reaching the Data Source](https://userguide.qualytics.io/source-datastore/datastore/troubleshooting/#reaching-the-data-source).

*Last updated: November 17, 2026.*