# Metric Check Comparisons

Source: https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/comparisons/

The comparison decides what a Metric check measures and what Min and Max bound. There are three: **Absolute Value** bounds the field's value itself, while **Absolute Change** and **Percentage Change** bound how much it moved since the previous measurement.

> **Warning: Different from the Volumetric check comparisons**
>
> The [Volumetric](https://userguide.qualytics.io/data-quality-checks/volumetric/deep-dive/comparisons/) check uses the same three comparison names, but its behavior is entirely different. A Volumetric check measures the container's row count and compares it with the daily counts of earlier calendar days. A Metric check measures one field's value on a single row and compares it with the measurement of the previous Scan of the same read strategy. Do not carry limits or expectations from one check to the other.

## Absolute Value

Absolute Value asks: *is the value inside `[Min, Max]`?*

- **What is compared.** The field's value on the one row the Scan evaluates.
- **What Min and Max mean.** Values of the field, in its own unit.
- **Anomaly rule.** A value below Min or above Max raises an anomaly. Both limits are inclusive.
- **History.** None. Every Scan is compared directly, including the first.
- **Best for.** A KPI with a known acceptable range, such as a rate between 2% and 8%.

**Example.** Min `0.02`, Max `0.08`:

| Scan | Value |
| --- | --- |
| Monday | 0.051 |
| Tuesday | 0.012 |
| Wednesday | 0.047 |

## Absolute Change

Absolute Change asks: *did the value move by more than expected since the previous Scan?*

- **What is compared.** The value against the most recent measurement from an earlier Scan of the same read strategy (Incremental or Full).
- **What Min and Max mean.** Movements, in the field's unit. A negative Min allows the value to fall by up to that amount, and a positive Min requires it to grow by at least that amount.
- **Anomaly rule.** If the value is below the previous measurement plus Min, or above the previous measurement plus Max, an anomaly is raised. Both limits are inclusive.
- **History.** The first Scan of each read strategy only records the value.
- **Best for.** A value that drifts over time but should not jump between Scans, such as a running balance.

**Example.** Min `30`, Max `70`:

| Scan | Previous measurement | Value | Change |
| --- | --- | --- | --- |
| #1 | - | 100 | - |
| #2 | 100 | 150 | 50 |
| #3 | 150 | 220 | 70 |
| #4 | 220 | 300 | 80 |

## Percentage Change

Percentage Change asks: *did the value move by more than a given percentage since the previous Scan?*

- **What is compared.** The same pair as Absolute Change: the value against the most recent measurement of the same read strategy.
- **What Min and Max mean.** Percentages of the previous measurement. The form labels them **Min Percentage** and **Max Percentage** and takes values in percent (enter `-20` for a 20% decrease). Through the API they are decimals (`-0.2`).
- **Anomaly rule.** If the change, as a percentage of the previous measurement, falls below Min or above Max, an anomaly is raised. Both limits are inclusive.
- **History.** The first Scan of each read strategy only records the value.
- **Best for.** A total whose scale varies, where a fixed amount would be too strict on a big day and too loose on a small one.

**Example.** Min `-20`, Max `50`:

| Scan | Previous measurement | Value | Change |
| --- | --- | --- | --- |
| #1 | - | 100 | - |
| #2 | 100 | 150 | 50% |
| #3 | 150 | 120 | -20% |
| #4 | 120 | 65 | -45.83% |

After Scan #4, the anomalous value becomes the previous measurement: Scan #5 is compared with 65, not with 120.

## Choosing a Comparison

| The expectation you want to enforce | Comparison |
| --- | --- |
| The value always stays between X and Y | Absolute Value |
| The value never moves by more than a fixed amount between Scans | Absolute Change |
| The value never moves by more than a percentage between Scans | Percentage Change |

The comparison is chosen when the check is created and is locked after the first Scan that includes the check. See [How It Works](https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/how-it-works/#the-field-and-comparison-are-locked-after-the-first-scan).

## See Also

- **Anomaly Reporting**

  What the Record Anomaly reports, how to read its numbers, and what the source record shows.

  [Anomaly Reporting](https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/anomaly-reporting/)
- **Examples**

  Three production scenarios: a daily revenue total, a rate for one region, and a running balance.

  [Examples](https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/examples/)
- **Best Practices**

  Guidelines for putting the value in one row, choosing the read strategy and comparison, and reading change anomalies.

  [Best Practices](https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/best-practices/)
- **Permissions**

  The team permission each action needs: view, create, edit, validate, archive, restore, and delete.

  [Permissions](https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/permissions/)
- **How It Works**

  The complete reference: definition, why the check needs exactly one row, the properties, the previous measurement, and the locks after the first Scan.

  [How It Works](https://userguide.qualytics.io/data-quality-checks/metric/deep-dive/how-it-works/)

*Last updated: October 12, 2026.*